Well & Radon GuidePrivate well water & radon, by county

Directory / Crawford County, Missouri

Private well water & radon

Crawford County, Missouri

Crawford County has fewer USGS well records than Jefferson or Franklin, and most drinking-water parameters in the extract stayed below EPA health standards. Hardness is still consistently elevated, two iron samples met or exceeded the secondary standard, and one well had 231 pCi/L of radon-222 in water. Sparse data is not a clean bill of health — test your own well.

FIPS 29055 24 well sites 1,765 WQP results EPA Radon Zone 2

County well water snapshot

Real groundwater samples from wells reported to the USGS/EPA Water Quality Portal. These are not tests of individual household wells and are not EPA SDWIS public-water-system data. Many records are historical. Use them to decide what to test — then test your own well.

24well sites
1,765result records
1934–2016sample years in extract

Site type: Well · Media: Water (Groundwater) · Provider: NWIS (USGS)

Parameter Samples / sites Date range Min / median / max Compared with EPA standard Notes
Nitrate
mg/L as N
33 numeric
21 sites
1934-03-06 to 2016-06-01 0 / 0.136 / 0.723 0 at or above MCL 10 mg/L as N
Below standard
—
Inorganic nitrogen (nitrate and nitrite)
mg/L as N
8 numeric
9 sites
1990-11-27 to 2016-06-01 0.14 / 0.295 / 0.6 0 at or above MCL 10 mg/L as N
Below standard
—
Arsenic
µg/L
1 numeric
2 sites
1970-12-07 to 2016-06-01 0.1 / 0.1 / 0.1 0 at or above MCL 10 µg/L
Below standard
Only two arsenic results exist in this extract. Sparse data is not evidence that arsenic is absent from untested wells.
Lead
µg/L
2 numeric
6 sites
1970-12-07 to 2016-06-01 0.588 / 5.294 / 10 0 at or above Action Level 15 µg/L
Below standard
Lead should still be tested at the tap. Household plumbing is a common source that monitoring wells may not capture.
Hardness, Ca, Mg
mg/L as CaCO3
20 numeric
20 sites
1934-03-06 to 2016-06-01 120 / 200 / 310 No EPA MCL / SMCL
No EPA MCL
EPA has not set an MCL or SMCL for hardness. All 20 numeric hardness results were at least 120 mg/L as CaCO3.
Iron
mg/L
12 numeric
17 sites
1934-03-06 to 2016-06-01 0.01 / 0.045 / 0.7 2 samples at or above SMCL 0.3 mg/L
At or above standard
Two samples were at or above 0.3 mg/L: 0.7 mg/L at USGS-380551091215001 on 1971-04-15 and 0.3 mg/L at USGS-380121091103601 on 1965-12-12.
Manganese
mg/L
6 numeric
11 sites
1966-04-11 to 2016-06-01 0 / 0 / 0.026 0 at or above SMCL 0.05 mg/L
Below standard
—
Escherichia coli
cfu/100mL
6 numeric
5 sites
1997-05-20 to 2016-06-01 0 / 0 / 0 0 detected / 7 not detected
Below standard
Portal bacteria results are few and all non-detect. Test your own well every year.
Fluoride
mg/L
12 numeric
13 sites
1964-06-22 to 2016-06-01 0 / 0.07 / 0.3 0 at or above MCL 4 mg/L
Below standard
—
Chloride
mg/L
21 numeric
21 sites
1934-03-06 to 2016-06-01 0.98 / 5.2 / 60 0 at or above SMCL 250 mg/L
Below standard
—
Sulfate
mg/L
18 numeric
19 sites
1934-03-06 to 2016-06-01 1.5 / 7.95 / 32 0 at or above SMCL 250 mg/L
Below standard
—
Total dissolved solids
mg/L
33 numeric
20 sites
1934-03-06 to 2016-06-01 118 / 226 / 378 0 at or above SMCL 500 mg/L
Below standard
—
Uranium
µg/L
1 numeric
1 sites
2016-06-01 to 2016-06-01 0.371 / 0.371 / 0.371 0 at or above MCL 30 µg/L
Below standard
—
Radium-226
pCi/L
1 numeric
1 sites
2016-06-01 to 2016-06-01 0.08 / 0.08 / 0.08 No EPA MCL / SMCL
Below standard
One 2016 sample had Ra-226 of 0.08 pCi/L. The paired Ra-228 result was −0.22 pCi/L, a below-background radiochemistry value, not a negative concentration in the ordinary sense. Combined, these are far below the 5 pCi/L MCL.
Radon-222 (in water)
pCi/L
1 numeric
1 sites
2016-06-01 to 2016-06-01 231 / 231 / 231 No EPA MCL / SMCL
No EPA MCL
A single 2016 radon-222 groundwater result was 231 pCi/L. There is no federal drinking-water MCL for radon. This does not replace an indoor-air test.

Computed from data/raw/crawford-county-mo-wqp-results.csv on 2026-11-26. Nitrate units were normalized to mg/L as N before statistics.

Recommended test panel for this county

Tailored to what actually shows up in the local well records, plus the standard annual coliform and nitrate baseline.

  1. Total coliform and E. coli. Annual baseline for every private well. Portal bacteria records here are few and all non-detect.
  2. Nitrate (as nitrogen). Annual and home-purchase / pregnancy baseline, even though this extract’s nitrate values were low.
  3. Hardness and iron. The clearest local aesthetic pattern: consistently hard water, with two historic iron results at or above the secondary standard.
  4. Lead at the tap and a metals panel (arsenic, manganese, fluoride). Records for these metals are sparse. A current household test is the only way to know.
  5. Indoor radon (air), then radon in well water if air is elevated. The county is EPA Zone 2, and one 2016 USGS sample found 231 pCi/L of radon-222 in groundwater.

Radon in Crawford County

Zone 2 — Moderate potential

EPA’s official zone assignment for Crawford County is Zone 2. Zone 2 (orange zones): Moderate potential; average indoor radon levels may be between 2 and 4 pCi/L (75–150 Bq/m³).

EPA says the Map of Radon Zones should not be used to determine whether an individual home should be tested. Homes with elevated radon have been found in all three zones. All homes should be tested for radon.

Fix your home if the radon level is 4 pCi/L or higher. Consider fixing if the level is between 2 and 4 pCi/L.

EPA Map of Radon Zones · JSON extract https://www.epa.gov/system/files/other-files/2024-06/radon-zones-202406.json · page last updated September 16, 2026 · verified 2026-11-26

CDC and Missouri testing statistics

The CDC Environmental Public Health Tracking Network publishes county-level radon testing data (lab-reported tests and, for some states, state-program tests), including counts and percents by concentration band, plus median and maximum pre-mitigation levels. Missouri DHSS also publishes a county-level dashboard of its 2003–2023 residential testing program. Official machine-readable county figures could not be extracted from those interactive tools on 2026-11-26 (the CDC API endpoints tried here returned empty tables or rate-limited errors). This directory therefore does not invent county-level CDC percentages. Use the official dashboards for county charts, and the DHSS statewide finding that 1 in 3 tested homes exceeded 4.0 pCi/L.

Data from the MDHSS residential radon testing program shows that 1 in 3 homes tested had indoor radon results that exceeded the recommended action level of 4.0 pCi/L. The Missouri Radon Dashboard displays residential radon testing results gathered by the program from 2003 to 2023, by county.

CDC radon tracking · Missouri radon dashboard

Verified 2026-11-26

Radon in private well water

Because indoor-air radon is the larger health concern, EPA recommends testing the air in your home first. If indoor air is elevated and you have a private well, EPA recommends testing the well water for radon. There is no federal MCL for radon in drinking water.

National Radon Program Services (EPA-funded) describes a commonly used estimate: subtract about 1 pCi/L from your indoor-air result for every 10,000 pCi/L found in the water.

The Water Quality Portal extract includes one radon-222 groundwater result in Crawford County (2016) of 231 pCi/L. There is no federal MCL for radon in water.

Sources: EPA archived consumer fact sheet, Radon in Drinking Water: Questions and Answers · National Radon Program Services — Testing for Radon in Water · EPA RadTown — Natural Radionuclides in Private Wells · verified 2026-11-26

Free Missouri test kits and certified radon pros

Missouri Department of Health and Senior Services — Radon Program. Short-term indoor radon test kits at no cost to Missouri residents, while supplies last, limit one per household. Request a kit on the DHSS radon page and use coupon code TESTING. The kit includes instructions and a postage-paid return envelope. DHSS also takes requests at 573-751-6102. Mail the completed test back promptly; the lab cannot give an accurate result if more than seven days pass between the end of the test and the lab's receipt.

DHSS says radon professionals should be used for testing that is part of a legal transaction. DHSS also notes that average mitigation costs range from $500 to $2,500 depending on the home, and recommends contractors certified by NRPP or NRSB.

Phone: 573-751-6102 (toll-free 866-628-9891) · [email protected] · Environmental Epidemiology, P.O. Box 570, Jefferson City, MO 65102

Request a free DHSS radon kit Find an NRPP professional

DHSS Radon program · verified 2026-11-26. Coupon code published on that page: TESTING.

Certified labs and state testing options

Missouri DNR states that a certified laboratory must be used for Public Drinking Water Branch compliance testing, but analysis of water samples from private residences or private wells does not have to be done by a certified laboratory. Certified commercial labs are still a strong choice for homeowners, especially for real-estate or legal testing.

Crawford County Nursing Service (local public health agency)

202 West Main St., P.O. Box 367, Steelville, MO 65565

Phone: 573-775-2555 · Fax: 573-775-3826

Contact the local public health agency to request an MSPHL private-well sample collection kit and instructions. DHSS recommends starting with your LPHA; kits can also be requested from DHSS Environmental Epidemiology if needed.

Official page · verified 2026-11-26

Missouri State Public Health Laboratory (MSPHL)

101 N. Chestnut Street, P.O. Box 570, Jefferson City, MO 65102-0570 · Phone: 573-751-3334 · Email: [email protected]

  • Routine private-well bacteriological testing for total coliform and E. coli (presence/absence).
  • Iron bacteria testing by special request.
  • Chemical panels for private drinking water: New Well Series (fluoride, chloride, nitrate/nitrogen, sulfate, iron, manganese, and lead) and a Full Panel of minerals, nutrients, and metals (including arsenic, uranium, and many others).

Routine bacteriological test handling fee: $10 — Check or money order only; must be included with the sample or testing will not be performed.

Chemical testing (New Well Series or Full Panel): Not published as a single statewide price on the MSPHL chemical-testing page — Fees can vary by the local public health agency that issues the kit. Contact your LPHA or DHSS Environmental Epidemiology.

Samples must be submitted in MSPHL collection kits, available through local public health agencies or State District Health Offices (or via the DHSS kit request form). Samples must arrive at the laboratory and testing must be started within 48 hours of collection. The MSPHL statewide courier may be used at no charge. DHSS offers this as a public-health service and does not offer private-well testing for real-estate transactions — use a private laboratory for those.

Official source · Verified 2026-11-26

Franklin County Lab

7419 Highway 47, Suite A, Union, MO 63084 · Missouri DNR's certified laboratory list uses this Suite A address. The lab's own contact page lists 7419 State Highway 47, Union, MO 63084. · Phone: 636-583-9288 · Email: [email protected]

Missouri DNR certified microbiological laboratory, Certificate No. 700, commercial, expiration Oct 31, 2028, supervisor Kristen Wideman.

  • State-certified Total Coliform and E. coli testing.
  • Lead, nitrate, and nitrite testing, plus Water Check panels (metals, inorganics, organics, pesticides depending on the panel).

Standard bacteria test (Total Coliform and E. coli): $30 — Published on the lab's FAQ page.

Sample collection service call: About $200 on average — An additional service-call fee applies outside a one-hour radius from Union, MO. Exact pricing for advanced chemical panels varies — contact the lab for a quote.

Homeowners, realtors, builders, and public systems; the lab states it serves Franklin, St. Louis, Jefferson, Crawford, and St. Charles counties.

Official source · Verified 2026-11-26

Environmental Analysis South

4000 E. Jackson Blvd., Jackson, MO 63755 · Phone: 573-204-8817 · David Warren, CEO/Analyst

Missouri DNR certified microbiological laboratory, Certificate No. 660, commercial, expiration Feb 28, 2028.

  • DNR-certified commercial microbiological drinking-water laboratory (for-hire compliance analyses).

Listed by DNR as a commercial (for-hire) certified microbiological lab. Confirm current homeowner kit availability and pricing directly with the laboratory.

Official source · Verified 2026-11-26

EMSL Analytical Inc. — St. Louis

100 Green Park Industrial Court, St. Louis, MO 63123 · Phone: 314-577-0150 · Jeff Siria, Laboratory Manager

Missouri DNR certified microbiological laboratory, Certificate No. 165, commercial, expiration Aug 31, 2029.

Missouri DNR certified chemical laboratory, Certificate No. 165, commercial, expiration May 31, 2027, for antimony, arsenic, barium, beryllium, cadmium, chromium, copper, fluoride, lead, nickel, nitrate, nitrite, selenium, and thallium.

  • Certified microbiological and inorganic chemical drinking-water analyses.

Official source · Verified 2026-11-26

Brothers Lab Services

10 Kimler Drive, Suite G, Maryland Heights, MO 63043 · Phone: 888-893-6578 · Kaitlyn Cheatham, Laboratory Director

Missouri DNR certified chemical laboratory, Certificate No. 11020, commercial, expiration Apr 30, 2028, for antimony, arsenic, barium, beryllium, cadmium, chromium, copper, fluoride, lead, nickel, nitrate, nitrite, selenium, and thallium.

  • Certified inorganic chemical drinking-water analyses, including arsenic, lead, nitrate, and nitrite.

Official source · Verified 2026-11-26

Eurofins St. Louis Laboratory

13715 Rider Trail N., Earth City, MO 63045 · Phone: 314-298-8566 · Kristen Ely

Missouri DNR certified chemical/radiochemistry laboratory, Certificate No. 780, commercial, expiration Jun 30, 2028, for gross alpha, gross beta, radium-226, radium-228, strontium-90, tritium, and uranium.

  • Certified radiochemistry analyses useful when a well needs radionuclide testing (gross alpha, radium, uranium). This listing does not by itself confirm radon-in-water testing — ask the lab.

Official source · Verified 2026-11-26

DNR laboratory lists: microbiological and chemical. Verified 2026-11-26.

Treatment options matched to local issues

  1. Coliform or E. coli. Fix sanitary defects, shock-chlorinate, and retest. Persistent problems may need UV or continuous chlorination.
  2. Hardness. A cation-exchange water softener is the usual whole-house treatment for scale and soap issues.
  3. Iron staining. An iron filter or, in some cases, a softener, sized to a current lab report.
  4. Nitrate, arsenic, or lead (if a current test is high). Point-of-use reverse osmosis or other certified systems; inspect plumbing for lead.
  5. Indoor radon. Confirmed indoor-air results at or above 4 pCi/L should be mitigated by an NRPP- or NRSB-certified professional. If air is high and you have a private well, test the water for radon.

Start with free or low-cost state testing when available. If you prefer mail-in lab kits or whole-house treatment, here are trusted options (some links may earn a referral commission at no extra cost to you):

Spruce radon test kits (radon.com)

Short-term (Air Chek) and long-term (Alpha Track) radon-in-air kits, plus radon-in-water tests, sold at radon.com — Spruce's official consumer store.

Shop Spruce radon test kits

Methodology and sources

Every number, lab name, phone number, address, fee, and health standard on this page was taken from a public source checked on 2026-11-26. Water-quality statistics were computed directly from the downloaded Water Quality Portal CSV (well / groundwater only). Nitrate reported as mg/L as NO3 was converted to mg/L as N. Non-detects are counted separately and are not treated as exceedances.